top of page

.png)
Clearwater Insights


Chiller Inspections
An annual inspection of your chillers, and especially of your condensers, is a preventative maintenance endeavor that must never be...
Dec 2, 20202 min read


Boiler Burner Tune-Ups - A Good Investment
At Chemtex, we focus on the water side of your boiler, emphasizing how to protect tubes from corrosion and scale; how to minimize...
Nov 17, 20203 min read


Nov 9, 20200 min read


Benefits of Reverse Osmosis
Reverse osmosis (RO) is a water treatment process in which water is forced under pressure though a semi permeable membrane, which...
Nov 4, 20202 min read


Tolerable Iron Levels in Glycol Loops
Many HVAC systems are treated with glycol. Glycol-based fluids are commonly used for secondary cooling and heating applications, as well...
Oct 26, 20202 min read


How to Overcome Today's Skilled Labor Shortage
Is your business confronting a shortage of skilled labor? According to a 2018 study by Korn Ferry , a global organizational consulting...
Oct 21, 20202 min read


Proper Boiler Chemical Feed Points
Boiler plants vary. So do their chemical demands, and their capacities for chemical feeding. It is important to choose the optimal...
Oct 19, 20202 min read


Boiler Storage
When the boiler is taken off-line and will not be in operation, it is important to follow proper lay-up procedures. In normal boiler...
Oct 17, 20203 min read


Managing Condensate at Boiler Start–Up
October is the month for seasonal boiler preparation. With winter on the way, it’s time to get your boiler system up and running for the...
Oct 16, 20202 min read


Strategic Delegating for Greater Productivity
If you’re always thinking “there aren’t enough hours in the day,” we’ve got a suggestion. Delegating. While delegating can sometimes feel...
Sep 22, 20202 min read


It's That Time of Year: Boiler Start-Up Season
Boiler start-up and filling a boiler is a critical process, and needs to be done correctly. How you fill and start your boiler can have a...
Sep 21, 20203 min read


Sep 9, 20200 min read


Energy Efficient Practices in Industrial/Commercial Buildings
Energy efficient practices can have a big positive impact on the bottom line at manufacturing plants. According to a U.S. Department of...
Aug 18, 20203 min read


ASHRAE 188 – Driving Cooling Tower Costs
ANSI/ASHRAE Standard 188-2018 , titled Legionellosis: Risk Management for Building Water Systems , establishes minimum legionellosis risk...
Aug 17, 20202 min read


Legionella Testing and Legislation in Florida
In December 2019, Florida State Senator Joe Gruters introduced legislation (23-00188-20) proposing regulation of the monitoring, control...
Aug 12, 20202 min read


Legionella Times Change NY City
While the public may have forgotten, most of us in water treatment remember the Legionnaires’ disease outbreak in 2015 in the Bronx,...
Aug 10, 20202 min read


OSHA Compliance for Hazardous Waste
OSHA compliance is, and should be, a major focus for every industry, in every department, at all times. The OSHA is the Occupational...
Jul 9, 20203 min read


Legionella Testing Methods
Testing for Legionella is a routine part of any water maintenance program. There are three common laboratory test methods for Legionella...
Jul 6, 20202 min read


Biocides To Consider For Minimizing Legionella Risk
As we discussed in our recent post, Best Biocides for Cooling Towers , there are many biocides available for reducing the risk of...
Jul 6, 20202 min read


Best Biocides For Use In Cooling Towers
Routine biocide application is a standard treatment of cooling tower water, to ensure that bacteria are under control and the potential...
Jul 2, 20202 min read
bottom of page